5900C Radar Level Gauge
2=Performance class: ±2 mm (0.08 in.) instrument accuracy
S=Safety certification (SIS): Certified IEC 61508 SIL 2 capable
1=Redundancy: None. Single radar level gauge electronics
F=Tankbus: Power and communication : Bus powered 2-wire FOUNDATION Fieldbus (IEC 61158)
I1=Hazardous location certification : ATEX Intrinsic Safety
0= Custody transfer type approval : None
1=Level measurement method : 10 GHz FMCW radar technology
A=Housing : Standard enclosure, polyurethane-covered aluminum. IP 66/67
2=Cable entry/Conduit connections : M20 x 1.5 adapters, female thread. (2 adapters and 1 plug included)
1C=Antenna : Cone antenna
8=Antenna size : 8 in. / DN 200, Ø=189 mm (7.4 in.)
S=Antenna material : SST AISI 316/316L and SST EN 1.4401/1.4404
PV=Tank seal : PTFE with Viton fluoroelastomer O-rings
8A=Tank connection : 8 in. Class 150
0=Antenna options : None